Le Cache Loft 1400 Built In #2333
Overview
NOW WITH THE MOST ADVANCED COOLING UNITS FROM CELLARPRO! Designed to be built-in, this wine cabinet is perfect for sophisticated wine collectors seeking simplicity and style and is ideally suited for modern dwellings.
Details
Le Cache Loft 1400 Wine Cabinet Built-In (P/N 2333). This wine cabinet is designed to be placed in a closet or enclosed space, includes our front-vent hood and grill and is designed to be built-in.
Key features include:
Key features include:
- Tinted double-paned glass door
- Sealed seams and premium insulation
- All-wood Universal racking easily accommodates large-format wine bottles (including most Champagne bottles)
- The door can be hinged on either side, and is available in a choice of black matte or satin silver finishes
- Includes CellarPro cooling unit, hood and venting to be compatible for built-in installation
- Ships fully assembled
Features
- Aluminum door
- Double-pane tinted glass
- Black laminate exterior
- Foil-backed polyisocyanurate insulation
- CellarPro wine cooling unit (made in USA)
- Electronic Thermostat and Digital Display
- Adjustable Humidity Control
- All-wood Interlock racks
- Five-year warranty on the cooling system
- Two-year warranty on entire cabinet
Configurations
COOLING UNIT OVERVIEW
Loft wine cabinets from Le Cache come with a choice of 2 CellarPro cooling units included in the price of the wine cabinet. The 2 CellarPro cooling units are dimensionally sized exactly alike, and therefore they are interchangeable. However, the 2 cooling units differ in terms of their BTUH cooling output and the level of noise that they produce. Each of the 2 cooling units is discussed below.
For more information about sizing the best cooling unit for your cabinet, refer to our Cooling Unit Buying Guide for Wine Cabinets.
CELLARPRO 1800QT-ECX
The 1800QT-ECX cooling unit is designed for residential use in a temperature-controlled environment. The 1800QT-ECX easily can maintain 55F in our largest wine cabinets.
This unit can be used with our front duct hood.
Key Stats: 1380 BTUH at 55F, 45 dbA installed in a cabinet.
CELLARPRO 1800XT-ECX
The 1800XT-ECX is approximately 5% more powerful and 3 decibels louder than the 1800QT-ECX cooling unit, because it uses more powerful fans. As a result, The 1800XT-ECX is ideally suited for garage environments (with temperatures ranging from 40F to 95F), commercial environments (where the cellar is frequently accessed) and installations with our front-duct hood..
Key Stats: 1456 BTUH at 55F, 48 dbA installed in a cabinet.
Loft wine cabinets from Le Cache come with a choice of 2 CellarPro cooling units included in the price of the wine cabinet. The 2 CellarPro cooling units are dimensionally sized exactly alike, and therefore they are interchangeable. However, the 2 cooling units differ in terms of their BTUH cooling output and the level of noise that they produce. Each of the 2 cooling units is discussed below.
For more information about sizing the best cooling unit for your cabinet, refer to our Cooling Unit Buying Guide for Wine Cabinets.
CELLARPRO 1800QT-ECX
The 1800QT-ECX cooling unit is designed for residential use in a temperature-controlled environment. The 1800QT-ECX easily can maintain 55F in our largest wine cabinets.
This unit can be used with our front duct hood.
Key Stats: 1380 BTUH at 55F, 45 dbA installed in a cabinet.
CELLARPRO 1800XT-ECX
The 1800XT-ECX is approximately 5% more powerful and 3 decibels louder than the 1800QT-ECX cooling unit, because it uses more powerful fans. As a result, The 1800XT-ECX is ideally suited for garage environments (with temperatures ranging from 40F to 95F), commercial environments (where the cellar is frequently accessed) and installations with our front-duct hood..
Key Stats: 1456 BTUH at 55F, 48 dbA installed in a cabinet.
Specs & Resources
Brand: Le Cache
Size: 31w x 29d x 79h (in)
Weight: 320 lbs
Power/Rating:
115V AC / 60 Hz
Running / Startup Amps (compressor)
- CellarPro 1800QTL-ECX: 2.4 Amps / 14.2 Amps
- CellarPro 1800QT-ECX: 2.9 Amps / 20.1 Amps
- CellarPro 1800XT-ECX: 3.0 Amps / 20.1 Amps
Thermal Load Calculations
Capacity: 172 bottles
Double Deep storage
Racked Slots: 160 bottles (3.8 inch slots)
Bulk Space: approximately 12 bottles (stacked)
Material: Melamine Laminate
Warranty:
2 Years (Cabinet) / 5 Years (Cooling Unit)
Optional Extended Warranty
Click on one of the following links for more information:
Size: 31w x 29d x 79h (in)
Weight: 320 lbs
Power/Rating:
115V AC / 60 Hz
Running / Startup Amps (compressor)
- CellarPro 1800QTL-ECX: 2.4 Amps / 14.2 Amps
- CellarPro 1800QT-ECX: 2.9 Amps / 20.1 Amps
- CellarPro 1800XT-ECX: 3.0 Amps / 20.1 Amps
Thermal Load Calculations
Capacity: 172 bottles
Double Deep storage
Racked Slots: 160 bottles (3.8 inch slots)
Bulk Space: approximately 12 bottles (stacked)
Material: Melamine Laminate
Warranty:
2 Years (Cabinet) / 5 Years (Cooling Unit)
Optional Extended Warranty
Click on one of the following links for more information:
- Owner's Manual
- Cooling Unit Selection Guide
- Placement Requirements
- Wine Cabinet Delivery & Inspection Instructions
- Wine Cabinet Filter: Top View
- Top View
- Top View
- Adjustable Humidity Performance Chart
- Wine Cabinet Monthly Operating Cost
- Cooling Unit Sound Performance - this cabinet includes our 1800XT and our front-vent hood, which will generate sound levels equivalent to the 1800QTL-ECX
Bottle Capacity
BOTTLE CAPACITY
Please note:
(1) We count the top of the racks as 1 row when counting rows in our racks.
(2) Every slot in the racks is 3 3/4" and sized to fit oversized Burgundy and most Champagne-size bottles.
(3) Bulk storage is located atop the racks (except for the first row atop the racks). Bulk storage capacity is based on Bordeaux-size bottles.
(4) Total capacity is the sum of racked plus bulk capacity, with double-deep storage in all cases except the Contemporary Credenza (which is single-deep). Usable capacity may be lower by 2-3 bottles when the first few cells under the cooling unit are left empty for proper air circulation.
Bottle Capacity | |||||
Model | Rows | Columns | Racked | Bulk | Total |
1400 | 14 | 6 | 160 | 12 | 172 |
2400 | 16 | 8 | 256 | 30 | 286 |
3100 | 16 | 10 | 320 | 48 | 368 |
3800 | 17 | 12 | 408 | 50 | 458 |
5200 | 17 | 16 | 544 | 78 | 622 |
Credenza - Contemporary | 8 5 | 6 9 | 93 | 22 | 115 |
Credenza - Euro & Mission | 7 5 | 5 8 | 150 | 30 | 180 |
Please note:
(1) We count the top of the racks as 1 row when counting rows in our racks.
(2) Every slot in the racks is 3 3/4" and sized to fit oversized Burgundy and most Champagne-size bottles.
(3) Bulk storage is located atop the racks (except for the first row atop the racks). Bulk storage capacity is based on Bordeaux-size bottles.
(4) Total capacity is the sum of racked plus bulk capacity, with double-deep storage in all cases except the Contemporary Credenza (which is single-deep). Usable capacity may be lower by 2-3 bottles when the first few cells under the cooling unit are left empty for proper air circulation.
Q&A
Does a built-in cabinet require space above or behind the cabinet?
Built-in cabinets using our front-vent hoods do not require space behind or to the sides of the cabinet. Above the cabinet, with the front-vent hood installed, an additional 1 1/2 inches of space is required to remove the front-vent hood so that the cooling unit condenser coils can be cleaned periodically, or the filter replaced. Click on our placement requirements tab for more information.
Does the unit really need a dedicated circuit?
A: Yes, our units require dedicated circuits. When we say "dedicated circuit", we mean that the circuit shouldn't have any items that require heavy draws of electricity - eg other appliances, vacuum cleaners, big-screen TVs, blow-dryers - on the same circuit as the cooling unit. Lighting, computers or other low-draw items shouldn't be a problem on the same circuit.
Do I need the condensate drain line?
A: You don't need the drain line because our wine cabinets are constructed to be airtight when the doors are closed, and the cooling unit has a drain pan to catch excess condensation, which is burned off as the cooling unit runs.
Why does the fan run without the compressor?
A: We've programmed our fans to stay "on" for 3 minutes after the compressor turns "off", and then every 15 minutes thereafter , to recirculate moisture inside the cabinet. This fan cycle is extremely energy efficient, and increases the humidity inside the cabinet.
Built-in cabinets using our front-vent hoods do not require space behind or to the sides of the cabinet. Above the cabinet, with the front-vent hood installed, an additional 1 1/2 inches of space is required to remove the front-vent hood so that the cooling unit condenser coils can be cleaned periodically, or the filter replaced. Click on our placement requirements tab for more information.
Does the unit really need a dedicated circuit?
A: Yes, our units require dedicated circuits. When we say "dedicated circuit", we mean that the circuit shouldn't have any items that require heavy draws of electricity - eg other appliances, vacuum cleaners, big-screen TVs, blow-dryers - on the same circuit as the cooling unit. Lighting, computers or other low-draw items shouldn't be a problem on the same circuit.
Do I need the condensate drain line?
A: You don't need the drain line because our wine cabinets are constructed to be airtight when the doors are closed, and the cooling unit has a drain pan to catch excess condensation, which is burned off as the cooling unit runs.
Why does the fan run without the compressor?
A: We've programmed our fans to stay "on" for 3 minutes after the compressor turns "off", and then every 15 minutes thereafter , to recirculate moisture inside the cabinet. This fan cycle is extremely energy efficient, and increases the humidity inside the cabinet.